Get complete information related to latest Insulated Wire Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulated Wire Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulated Wire Scrap Tenders.
Tender For corrigendum : supply of 3 channel ecg machine , echo cardio graphic machine , heamodysis machine , anesthesia machine , laparoscopy surgery system , telescope 30 , camera 3 chip 3d laparoscopy camera , light source with cable , upper gi endoscope and endoscopy , electrocautery machine , high tech ot table , laparoscopic biopsy forces and punches , suction machine electric , dental x-ray machine , teeth set side lab and orthopedic work , advanced dental chair , orthroplasty set , femur nailing set , bone bowl femur plate screw set fore arm plating , distal tibia plate and screw set , c arm machine x-ray for ortho , proximal distal hurmers plate set , radiology 34 x-ray storage , proxmal hurmer plate set with screw , distal hurmer plate set with screw , locking compression plates proximal tibia plate and screw set , locking compression plates distal femur plate and screw set , ext fixater set with schanz pin , electric drill machine , phaco machine , perimetry b , green laser a , b. scan a , surgical microscope b , bmw trolley , food trolley for hospital ss
Tender For supply of side runner , double bed sheet , dustbin plastic , chair , runner carpet mat 5ft x 3ft , footmat 3ft x 2ft , plastic chair , fpo information bd for customers , hours of business bd , roll of honour board for fpm , postal rates bd , monitor 24 inch , ot pair , ip camera , poe switch 8 port , fiber cable , utp cable , dvr , 12 v adopter , pigtail , cable 2.5 mm , veh number plate , focus light out door
Tender For auction sale of scrap - mixed non strippable insulatedwires (copper 65%/pvc 35%),strippable telephone wire (as per lot description),scrap-0.75 mm insulatedwirescrap(copper- 57 %,pvc 43%),scrap - copper dust,scrap - hffr insulation
Tender For supply and installation of bera system - supply & installa tion of bera system, software and accessories -(specification mentioned as in the notice inviting tender document), specifications ecochg cortical aep (p100, llr, p300, mmn) am lr, eabr vestibular evoke d myogenic potenti al (vemp) algo rithm for emg rec tification assr, stacked abr (if p ossible). transducers - ins ert earphone s -td h headphone -bon e vibra tor - loudsp eaker stimulus - click (user-selecta ble from choi ces of 50, 100, 150, and 200 use) tone bur st (frequenci es 2 50 to 8 khz, choice of linear, henning, blackman or gaussian stimulus ramps for tone burst). t one pip speech: /p a/, /ta/, / ka/ ce- chirp, ce-chirp o cta ve bands mas king noise: pink a nd white noise p olarity: alternating , condensation, rar efaction intensity: 0 to 130 db spl or more repetition rates: 0.2 100 depending on modality data points: 256, 512, 1024 or more test protocols - unlimited, the system must support th e creation of user-d efined custom protocols capable of calculating a numeric correlation of t wo selected wavef orms to define simi larity between the collected waveforms objectively. c apable of performi ng weighted and unweighted addition and subtraction of selected waveforms. capable of sep arating abrdata c ollected with altern ating polarity stimu lation into its separate rarefaction and condensationwave form components. system must sup port automatic elec trode switching for singlechannel data collection such thatmanual movement of electrodesin the electrode cable is n ot required to colle ct ipsilateral data when changing the stimulus ear. syst em must be capabl e of applying user- specified post hoc digital filters durin g data analysis. s ystem must suppor t simultaneous revi ew of data frommultiple test sessions for the patient in th e same on-screen d isplay and report to facilitate monitorin g for changes over time. system mustprovide a means o f password-protecti ng thetransducer c alibration values to prevent inadvertent editing by unautho rised personnel. t he system should h ave an option for external direct printi ng of the report data export to hl7 protocols along wit h the facility to pro vide free api the system should have compliance with international regula tory standards of c e,fda, and iso. free period cali bration for the first three years and afte r three years of cal ibration along with amc support for5 years to be provid ed at the national i nstitute of speech a nd hearing com puter supplied alon g with the equipme nt needed to meet t he below requirem ents latest wind ows operating syst em processor whi ch is intel i 7 or hig her with clock spee d > 2.5mhz ram>= 8 gb and stora ge space ssd>= 5 00gb minimum 3 usb portsalong with 1 hdmi, 1eth ernet port warrant y of the computer b e three years mini mum equipmen t should be powere d using 240v 5ohz. the connection s hould be type d the software sup plied along with th e hardware should have the provision for free upgradation if a new version l aunches in the mar ket within the next five ye ars of the ins tallation also provide free software up dation and support as operating syste m upgradation hap pens penalty for thedelay in repair and delivery of the equipment and acc essories. the penal ty amount is calcul ated based on 24 h ours / 48 hours, an d 72 hours and if t he supplierdoes no t deliver the produc t within ten days of issuing the purchas e order, they should be blacklisted., cmc/amc cost a fter the completion of 3 years of warranty period ( 7 yearsof amc)